Checking for missing content type metadata ...

Checking for non-preferred file/folder path names (may take a long time depending on the number of files/folders) ...

Freeze–Thaw Dynamics in Engineering Spoil: Quantitative Characterization Based on Laboratory Experiments and Coupled Hydrothermal Modeling


Authors:
Owners: This resource does not have an owner who is an active HydroShare user. Contact CUAHSI (help@cuahsi.org) to determine if accessing this resource is possible.
Type: Resource
Storage: The size of this resource is 880.6 KB
Created: Oct 16, 2026 at 3:39 a.m. (UTC)
Last updated: Oct 16, 2026 at 3:43 a.m. (UTC)
Citation: See how to cite this resource
Sharing Status: Discoverable (Accessible via direct link sharing)
Views: 236
Downloads: 37
+1 Votes: Be the first one to 
 this.
Comments: No comments (yet)

Abstract

Freeze–thaw dynamics in heterogeneous engineering spoil reflect coupled thermal forcing, water availability, and particle-size-dependent transport, yet their combined controls remain poorly quantified. We combined four 96-h column experiments with a coupled hydrothermal model to quantify these controls in spoil collected from the Qinghai–Tibet Plateau. Experiments imposed cold-end temperatures of −5, −10, −15, and −20 °C; after evaluation, the model extended the analysis to initial volumetric water contents of 12–21% and uniformity coefficients of 12.94–22.56. For the −5 °C evaluation cycle, absolute mean bias errors were 0.92–2.11 °C for temperature and 0.06–0.57 percentage points for volumetric liquid-water content, with corresponding indices of agreement of 0.81–0.96 and 0.83–0.97. Lowering the cold-end temperature from −5 to −20 °C accelerated freezing-front propagation and increased peak pore-ice content at 8 cm from 12.1% to 22.4%. Higher initial water content buffered early cooling but increased maximum pore-ice content to 24.4% and prolonged thawing, whereas broader particle-size distributions enhanced heat transmission and deepened the frozen zone. Stable-stage freezing depth integrated these responses and was controlled primarily by cold-end temperature, with positive contributions from initial water content and particle-size distribution. Multiple linear regression explained 94.6% of the variance and achieved a held-out R² of 0.936, whereas a back-propagation neural network increased held-out R² to 0.970 and yielded a mean relative error of 3.49%. This work links mechanistic understanding of coupled hydrothermal processes with quantitative prediction, providing a basis for freeze–thaw risk assessment and engineering-spoil management in cold regions.

Subject Keywords

Content

How to Cite

Li, Z. (2026). Freeze–Thaw Dynamics in Engineering Spoil: Quantitative Characterization Based on Laboratory Experiments and Coupled Hydrothermal Modeling, HydroShare, http://www.hydroshare.org/resource/099345b33acb4a91989c502d7084b82b

This resource is shared under the Creative Commons Attribution CC BY.

http://creativecommons.org/licenses/by/4.0/
CC-BY

Comments

There are currently no comments

New Comment

required